Enter Inventory & QC From Remote PCs in Your Lab

Customers can remotely access BIOMIC V3 from multiple computers to perform selected functions. Examples include:

1) Review & confirm test results at a separate bench prior to LIS transfer
2) Enter QC & inventory including reagent/media lots from another workstation
3) Generate antibiograms and QC reports from your office



Learn more: 

Contact Giles Scientific

Bruker Maldi Biotyper now connects to BIOMIC V3 with MALDI-Link™

MALDI-Link™ automatically transfers ID results from Maldi Biotyper (Bruker) to BIOMIC® V3 (Giles Scientific). This direct interface eliminates manual transcription errors and additional LIS/LIMS interfacing via serial port or file exchange connection. This provides an ideal ID-AST solution for clinical microbiology labs. 



View MALDI-Link webpage >
View BIOMIC V3 website >

Contact Giles Scientific

MALDI-TOF Mass Spec for ID and BIOMIC V3 for AST



The BIOMIC V3 Microbiology System and MALDI-TOF Mass Spec Systems including the MALDI Biotyper (Bruker) and VITEK® MS (bioMerieux) provide an automated AST & ID solution for the microbiology lab. ID results can be sent from MALDI to BIOMIC V3 via LIS/LIMS. BIOMIC V3 automates AST tests including: antibiotic disk diffusion following CLSI/EUCAST/BSAC guidelines, Etest (bioMerieux), MIC Test Strips (Liofilchem) and 96-well microtiter plates. 

BIOMIC V3 also automates ID panels including API®(bioMerieux), RapID (Remel), BBL Crystal (BD), Liofilchem® ID Systems, colony count and chromogenic agar plates. Bar code entry and a 2-Way LIS/LIMS interface further speeds lab workflow. BIOMIC V3 serves as a primary or secondary AST-ID system for microbiology laboratories.

Visit BIOMIC V3 Website

Contact Giles Scientific

BIOMIC V3 Microbiology System


The BIOMIC V3 Microbiology System utilizes color digital imaging to automate the reading and interpretation of antibiotic susceptibility and organism identification tests for bacteria and yeast following current CLSI, EUCAST, or BSAC guidelines. BIOMIC V3 is an open system automating clinical microbiology tests including antibiotic disk diffusion, Etest® (bioMerieux), API® (bioMerieux), RapID™ (Remel), Crystal™ (BD), chromogenic agar, 96-well microtiter plates, MIC Test Strip (Liofilchem®), Liofilchem® AST & ID Systems and colony count plates. The Quality Control Center provides automated reading and recording of QC tests, lots and custom reports.

BIOMIC V3 provides an instant digital record of all test results and high resolution images. An LIS/LIMS interface combined with bar code reading and touch-screen entry on a 21 inch monitor offers microbiology laboratories an optimal setup to standardize, record and report test results for all lab sizes an setups.

Visit BIOMIC V3 Website

Contact Giles Scientific

2014 CLSI Guidelines in the BIOMIC V3 Microbiology System

The 2014 CLSI (Clinical Laboratory Standards Institute) M100-S24 guidelines & 2014 EUCAST Clinical Breakpoint Tables are updated in the BIOMIC V3 software. Changes include new or updated expert rules, updated AST breakpoints, and new or updated QC breakpoints. Disk diffusion and MIC test results are checked by the Resistance Monitoring Center™ for all resistance mechanisms, appropriate comments reported, and unlikely results flagged.

BIOMIC V3’s digital imaging technology automates the reading, interpretation, and reporting of CLSI, EUCAST and BSAC antibiotic disk diffusion tests, Etests® (bioMerieux), MIC Test Strips (Liofilchem®), 96-well microtiter plates, and identification panels including API® (bioMerieux), RapIDTM (Remel), BBLTM CrystalTM (BD), Liofilchem® ID Systems and chromogenic agar plates. Bar code entry and a 2-Way LIS/LIMS interface further speeds lab workflow. BIOMIC V3 serves as a primary or secondary AST-ID system for microbiology laboratories of all sizes and setups.  

New Reagent QC Testing & Reporting in the BIOMIC V3 Microbiology System

The BIOMIC V3 Microbiology System now contains an extensive reagent QC feature for electronic documentation of reagent QC tests (Oxidase, Catalase, PYR, etc) and lot information.  Customers define a list of reagents and templates including: lot number, manufacturer, expire date, in-use date, out-use date, quantity received, received by, visual inspection, QC results for positive and negative controls, expected results, frequency of testing, results acceptable, new lot, tech/supervisor initial, corrective action, comments, and the option to define custom fields.  Customers may attach up to 3 high resolution images with each QC test.  All reagent QC information and images are saved for future review.

BIOMIC V3’s digital imaging technology automates the reading, interpretation, and reporting of CLSI, EUCAST and BSAC antibiotic disk diffusion tests, Etests® (bioMerieux), MIC Test Strips (Liofilchem®), 96-well microtiter plates, and identification panels including API® (bioMerieux), RapIDTM (Remel), BBLTM CrystalTM (BD), Liofilchem® ID Systems and chromogenic agar plates. Bar code entry and a 2-Way LIS/LIMS interface further speeds lab workflow. BIOMIC V3 serves as a primary or secondary AST-ID system for microbiology laboratories of all sizes and setups.  


BIOMIC V3 Microbiology System Reads Liofilchem® AST and ID Products




Giles Scientific (USA) has collaborated with Liofilchem (Italy) to provide automated reading and interpretation of Liofilchem microbiology products including MIC Test Strips, ID and AST Systems, antibiotic disks, and chromogenic agar with the BIOMIC V3 Microbiology System. 

BIOMIC V3’s digital imaging technology automates the reading, interpretation, and reporting of Liofilchem products following EUCAST, CLSI or BSAC guidelines.  All test plate images are saved in high resolution for future review. Bar code reading and a bi-directional LIS/LIMS interface capability further speeds workflow.

“This collaboration fits perfectly with Liofilchem’s strategy. The proven quality of the BIOMIC V3 Microbiology System strengthens our position in clinical and industrial microbiology,” acknowledged Fabio Brocco, Chief Operating Officer, of Liofilchem. “We are convinced that Giles Scientific’s entrepreneurial spirit and 25+ years of global experience provide a solid foundation for future growth. We are excited to have such an experienced and dynamic team to collaborate with,” he added.

In addition to Liofilchem products, BIOMIC V3 reads a variety of clinical microbiology tests from other AST-ID manufacturers.  BIOMIC V3 serves as a primary or secondary AST-ID system for microbiology laboratories of all sizes and setups.